General Information

  • Technology : Arc splitting
  • Dimensions : W5,000×D4,900×H2,100 mm
  • Else : Double wall stainless steel water-cooled furnace; Expert operating system; The diagnosis function through remote control

Capacity(24H)

  • milling cutter
    • D6×50 mm = 4,500×5 = 22,500
    • D16×95 mm = 1,000×5 = 5,000
  • Insert
    • D20×H6 mm = 4,000×4 = 16,000
  • Hobs
    • D80×180 mm = 90×4 = 360

Turntable

  • D900×H850 mm

Power

  • 3×400V/160kW

Target

  • 727×178×18 mm (6Set)
  • 200/400×5

Coating types

  • Standards Coating
    • TiN, TiCN, TiAlN, AlTiN, MDT
  • Coating can be selected
    • TiAlSiN, AlCrTiN, DLC, NF1

Vacuum/Plasma

  • Vacuum chamber size
    • W1,200 x D1,200 x H1,200 mm
  • Vacuum chamber capacity
    • 1,500 L
  • Using plasma volume
    • D=900-950 x H730 mm

Electrical/Software

  • Industrial PC system
  • Simple and easy diagnosis and description system
  • Remote diagnosis through data machine or IP
  • Back up image file